Fluoride plastic magnetic pump troubleshooting repair methods

[Asia Pump Network News] Frequently encountered in daily life fluorine plastic magnetic pump failure, this time we need to go to the maintenance process, so as to be able to operate normally. So what are the common failures of fluorine plastic magnetic pump? How is it handled? Here to tell you Xiaobian fluorocarbon magnetic pump troubleshooting repair it! What if the magnetic pump encounters a problem? The following is the solution. (1) Shaft broken. CQB-type magnetic pump shaft material used is 99% of alumina ceramic, the main reason for the shaft is broken, because the pump runs dry, the shaft bearing dry wear and tear. Open the pump inspection can be seen when the bearing has been seriously damaged to prevent the pump broken off the main method is to avoid the air pump running. (2) bearing damage. CQB magnetic pump bearings are made of high-density carbon material, in case of pump water or pump impurities, it will cause the bearing damage. Cylindrical coupling inside and outside the rotor between the coaxial requirements if not guaranteed, it will directly affect the bearing life. (3) can not hit the liquid. Magnetic pump can not play the Liquid Pump is the most prone to failure, its reasons are more. First of all, check whether the pump suction pipe leaks, check the suction pipe air is exhausted, the amount of liquid filled in the magnetic pump is sufficient, inhalation tube whether there is debris clogging, check whether the pump is reversed (Especially after changing the motor or overhauling the power supply line), you should also pay attention to whether the suction height of the pump is too high. If the above inspection still can not be solved, the pump can be disassembled and checked to see if the pump shaft is broken. Check whether the moving ring and the static ring of the pump are intact, and whether the entire rotor can move in a small amount. If the axial movement difficulties, can check whether the carbon bearing with the pump shaft is too close. It is noteworthy that the magnetic pump repair several times to check the problem, should pay attention to the work of the magnetic coupling is normal. Bearings, inner magnetic rotors and spacers generate heat during operation, which increases the operating temperature and on the one hand reduces the power delivered and on the other hand gives rise to a great deal of hassle for the magnetic pumps that convey easily vaporized liquids. Magnetically transmitted power with temperature increases is a continuous decline in the curve, usually below the working temperature limit of the magnet, the decline of its transmission capacity is reversible, but above the limit temperature is irreversible, that is, the magnet cooling After losing the ability to pass the transfer can no longer be restored. Under special circumstances, when the magnetic coupling slips (out of step), the eddy current heat in the spacer increases rapidly and the temperature rises sharply. If it is not processed in time, the magnet will demagnetize and make the magnetic coupling fail. Therefore, the magnetic pump should design a reliable cooling system. The medium is not easy to vaporize, the cooling system is generally circulated by the impeller outlet or pump outlet leads to the liquid flow through the bearing and magnetic drive back to the suction port, the vaporization of the medium, the heat exchanger should be added or the liquid flow to the pump Of the tank, to avoid heat back to the suction port, for solid impurities or ferromagnetic impurities in the media, should consider filtering, high temperature medium, you should consider cooling to ensure that the magnetic coupling does not exceed the working temperature limit. In considering whether the speed is enough, we must first check the motor speed is normal, tachometer available for measurement, the motor speed is normal, you can consider whether there will be magnetic coupling slippage. (4) lack of lift. The reasons for this failure are: transmission medium air, impeller damage, speed is not enough, the proportion of liquid transport is too large, the flow is too large. (5) lack of traffic. The main reasons for the lack of flow are: impeller damage, speed is not enough, the lift is too high, the tube is clogged with debris and so on. The above is a common failure of the fluorine plastic magnetic pump, such as broken shaft, bearing damage, can not hit the liquid, lack of lift, insufficient flow and other maintenance methods, I hope you can keep in mind, so that after a similar problem encountered when you will not do anything It's Further reading: IFAT China Guangzhou exhibition industry leaders building water pump manufacturers ranking article belongs to Internet industry (Xiamen) Co., Ltd. All are welcome to reprint, please indicate the source and author of: Asian pumps Network Editor: lindj (QQ / WeChat:) Starting: http://beng.liuti.cn/ (Service Hotline:)

Pump Parts

For the convenience of customers, our company provides pump accessories, such as pump pipe joints, pump heads, refill ink bottles, capsule filters, etc. We focus on every detail because we understand your needs better.

Our products are highly recognized by customers at home and abroad, and we have established long-term cooperative relations with them. Products are widely used in medicine, laboratories, environmental protection technology, gas analysis and other fields. Friends in need are welcome to consult.

PP pump pipe joint,Pump accessories,Pump head,Capsule filter,Peristaltic pump head

Changzhou Yuanwang Fluid Technology Co., Ltd. , https://www.ywfluid.com